Specifications, Appendix – Watlow Series 94 User Manual

Page 33

Advertising
background image

W a t l o w S e r i e s 9 4

A p p e n d i x

A . 9

Appendix

(2291)
Control Mode
• Microprocessor-based, user selectable control modes
• Single input, dual output
• 2.5Hz Input Sampling Rate
• 1Hz Display Update Rate
• Automatic reset on power loss
Operator Interface
• Sealed membrane front panel
• Dual, four-digit red or green displays
• ‰Advance, ¿Up-arrow, ¯Down-arrow, and Reset keys
• User selectable screen display
Accuracy

• Calibration accuracy ±0.1% of span ±1°C at standard conditions

Exceptions:
Type T; 0.12% of span for -200°C to -50°C,

Types R and S; 0.15% of span for 0°C to 100°C

Types B; 0.24% of span for 870°C to 1700°C

• Accuracy span: 1000°F/540°C minimum

• Temperature stability: ±0.1 degree per degree change in

ambient

Sensors/Inputs
• Thermocouple, grounded or ungrounded sensors
• RTD 2- or 3-wire, platinum, 100

@ 0°C calibration to 0.003850

curve or 0.003916 curve; user selectable

• Sensor break protection de-energizes control output to protect

system

• °F or °C, user selectable
Input Range

Specified temperature ranges represent the controller’s operation-
al span.

• Thermocouple

Type J

32

to 1382°F

(0

to 750°C)

Type K

-328

to 2282°F

(-200

to 1250°C)

Type T

-328

to

662°F

(-200

to 350°C)

Type N

32

to 2282°F

(0

to 1250°C)

Type S

32

to 2642°F

(0

to 1450°C)

Type B

32

to 3308°F

(0

to 1820°C)

• RTD Resolution

-328

to 1292°F

(-200

to 700°C)

0.1°

-199.9 to 999.9°F
(-199.9 to 700.0°C)

Output 1 (Limit)
• Electromechanical relay

1

, Form C, 5A @ 120/240V~ maximum,

without contact suppression, rated resistive load, 5A @ 30VÎ
(dc)

2

. Minimum contact current: 100mA @5VÎ (dc).

Output 2 (Alarm)
• Electromechanical relay

1

, Form C, 5A @ 120/240V~ maximum,

without contact suppression, rated resistive load, 5A @ 30VÎ
(dc)

2

. Minimum contact current: 100mA @5VÎ (dc).

• Switched dc signal provides a non-isolated minimum turn on volt-

age of 3VÎ (dc) into a minimum 500

load; maximum on voltage

not greater than 12VÎ (dc) into an infinite load.

• Solid-state relay

2

, Form A, 0.5A @ 24V~ min., 264V~ max., opto-

isolated burst fire switched, without contact suppression. Off-state
output impedance is 31M

.

• Alarm output can be latching or non-latching, with separate high

and low values. Alarm silencing (inhibit) on power up.

Output Configurations
• Output 1
• Limit output is latching
• Output 2
User selectable as:
• Latching or non-latching
• Process alarm with flashing alarm message
• Process without alarm message
• Alarm with separate high and low set points
• Hysteresis: 1 to 9999°F, 0.1-999.9°F/1 to 5555°C, 0.1 to 555.5°C

switching differential

Line Voltage/Power
• 100-240V~, +10%

3

, -15%; (85-264V~) 50/60Hz, ±5%, 12VA max.

• 12-24Vı (ac/dc), +10%, -15%; (10-26Vı [ac/dc]) 50/60Hz, ±5%,

7 VA max.

• Data retention upon power failure via non-volatile memory
Operating Environment

3

• 32 to 149°F (0 to 65°C)
• 0 to 90% RH, non-condensing
Storage Temperature
• -40° to 185°F (-40° to 85°C)
Terminals
• #6 compression universal head screw terminals, accepts 20-14

gauge wire

• Torque to 1.4 Nm (12 in-lb)
Controller Weight
• 0.4 lb

(0.2 kg)

Shipping Weight
• 0.75 lb (0.34 kg)
Dimensions
• Compact 1⁄16 DIN size and IP65 (NEMA 4X)

4

, front panel makes

the Series 94 easy to apply and maintain in a wide variety of
applications. Unique mounting bezel, gasket and collar make
installation a snap. Use Greenlee punch 60287.

Overall Height:

55 mm

(2.1 inches)

Width:

55 mm

(2.1 inches)

Depth:

120 mm

(4.7 inches)

Bezel Height:

55 mm

(2.1 inches)

Width:

55 mm

(2.1 inches)

Depth:

15 mm

(0.6 inches)

Chassis Height:

45 mm

(1.8 inches)

Width:

45 mm

(1.8 inches)

Depth:

105 mm

(4.1 inches)

Agency Approvals
• FM3545, File #J.I.OD5A1.AF
• IP65, NEMA 4X and NEMA 12

4

CE approved (See Declaration of Conformity)

1

Electromechanical relays warranted for 100,000 closures only.
Solid-state switching devices recommended for applications
requiring fast cycle times or extended service life.

2

Switching inductive loads (relay coils, etc.) requires using an RC
suppressor. Quencharc from ITW PAKTRON is recommended,
Watlow part number 0804-0147-0000.

3

Operating environment is 0 to 60°C for line voltage exceeding 240V.

4

To effect IP65 (NEMA 4X) rating requires a minimum mounting
panel thickness of 1.5 mm (0.06 inch) and surface finish not
rougher than 812

µ

mm (0.32

µ

inch). Use Greenlee punch 60287.

Specifications

Advertising