3-9

IM 04L65B01-01EN

Connectable Devices and Interfaces

Name

Interface

1

RS-232

RS-422

RS-485

Ethernet

(connection port

number)

μR10000

Yes

Yes

Yes

34260

μR20000

Yes

Yes

Yes

34260

DX1000

Yes

Yes

Yes

34260

DX1000N

Yes

Yes

Yes

34260

DX1000T

Yes

Yes

Yes

34260

DX2000

Yes

Yes

Yes

34260

DX2000T

Yes

Yes

Yes

34260

CX1000

Yes

Yes

Yes

34260

CX2000

Yes

Yes

Yes

34260

FX1000

Yes

Yes

Yes

34260

MV1000

Yes

Yes

Yes

34260

MV2000

Yes

Yes

Yes

34260

MX100

No

No

Yes

34316

MW100

No

No

Yes

34316

DA100

Yes

Yes

Yes

34150

DR130

Yes

Yes

Yes

34150

DR230

Yes

Yes

Yes

34150

DR240

Yes

Yes

Yes

34150

GX10

2

Yes

Yes

Yes

34434

3

GX20

2

Yes

Yes

Yes

34434

3

GP10

2

Yes

Yes

Yes

34434

3

GP20

2

Yes

Yes

Yes

34434

3

DAQLOGGER

No

No

Yes

50280

4

DAQ32Plus

No

No

Yes

50278

4

MXLOGGER

No

No

Yes

50284

4

Devices supporting the Modbus

protocol

Yes

Yes

Yes

502

1 Yes: Supported No: Not supported
2 The GX/GP version R1.03.03 and later supports auto searching on an

Ethernet network.

3 The communication port can be specified on the GX/GP, but GA10 only

supports the default value, 34434.

4 DAQWORX software requires a port number parameter when the interface

is specified. (The port numbers above are initial values.)

Note

• To connect to DAQLOGGER, DAQ32Plus, or

MXLOGGER, enter the IP address of the PC in which

the software is installed.

• To connect to DAQLOGGER or DAQ32Plus, leave the

System No. at zero (default value).

To connect to MXLOGGER, select the System No.

that is being used in MXLOGGER.

• To register any of the following instruments by

specifying “Comm. Kind: Serial” and “User,” set the

A/D scan interval and FIFO writing interval of the

device to the same value.

DX1000, DX1000N, DX1000T, DX2000, DX2000T,

MV1000, MV2000, CX1000, CX2000, FX1000

• When connecting to a DXAdvanced (DX1000,

DX1000N, DX1000T, DX2000, or DX2000T) with the

/AS1 advanced security option through the Ethernet

interface, log in as an administrator to access the DX.

In this situation, only one administrator will be able to

log in.

To register a Modbus device:

page 3-10

Chapter 3 Configuring and Starting Data Collection and Recording

If you change the device settings after registering it to

the Devices List, click

Update Setting. The most recent

information will be retrieved from the device and applied.

click the Update Setting button.

Select the device, and

Registering Devices to the Registered Devices List
The Registered Devices List shows a list of devices

registered to the server. Therefore, in the initial page,

nothing will appear. When you add a new device to

the Devices List, it is also automatically added to the

Registered Devices List.

You can also drag a device from the Online Devices List

to register it.

Display filter

Update

Click

Update to retrieve the most recent list of devices

from the server.

You can set the Comm. Kind filter to display only the

devices using the specified interface. If you select

Serial,

the devices connected to the serial port of the server PC

will be displayed.

Note

The following information associated with the devices

in the Registered Devices List are not automatically

updated.

• Channel positions

• Channel enabled/disabled state

• Tag and tag number information

If you change these pieces of information on the device,

re-register the device to the Registered Devices List.

Note that the device will be registered as a separate

device. Because it is difficult to distinguish such devices,

we recommend that you delete unneeded devices and

devices that you change the information of.