7 adding marks, Adding marks -6 – Yokogawa Data Logging Software GA10 User Manual

Page 68

Advertising
background image

4-6

IM 04L65B01-01EN

• Data No.

A sequence number of collected data points taking

the first collected data point to be zero.

• Alarm indicator

The status of alarm level 1, alarm level 2, alarm

level 3, and alarm level 4, are displayed from the

left.

Displayed Content

Description

Red

Alarm occurrence

Green

Alarm release

Gray

Alarm not set

When

Alarm in the View menu is not checked,

alarm indicators are not shown.

To close the cursor value dialog box, click the

×

icon

in the upper right.

4.2.7 Adding Marks

You can add marks to data. To add a mark, specify the

mark string and the data to add the mark to.

1

Type the string in the mark edit box.

You can edit the displayed string as well as select

from a list of strings that you used in the past from

the drop-down menu. The drop-down menu displays

the most recent five strings.

Mark edit box

Current group

All groups

2

Click the data position you want to add a mark to
display a cursor.

To add a mark to the most recent data, perform step

3 in monitor mode. Step 2 is not necessary.

3

On the

Project menu, click Append Mark and then

Current Group or All Groups. Or, click the Current
Group
or All Groups icon.

A mark is added to the specified position.

Mark

• Adding a Mark to the Current Group

If you select Current Group, a mark is added only to the

group shown on the trend monitor.

• Adding a Mark to All Groups

If you select All Groups when data is being collected

using PC time, a mark is added to all groups.

If data is being collected using device time,

• In playback mode, a mark is added at the same

position as cursor A to all display groups that contain

tags of the same device and of the same collection

interval as the monitor set subwindow that you

added a mark to.

• In monitor mode, a mark is added to all groups.

• When Marks Are Overlapped

Sometimes marks overlap and the string of the lower

mark cannot be read. Clicking a mark with Shift held

down moves the mark to the back.

Note

• Marks that have been added cannot be deleted or

edited.

• Mark information is saved in data files. (Only binary

data files.) Mark information added to data positions

in files that have already been closed is saved in the

data file that is currently being recorded. You can view

these marks by displaying connected data files.

Chapter 4 Monitoring Data Collection

Advertising