Power vented blower unit number description – Sterling QVEB User Manual

Page 29

Advertising
background image

29

POWER VENTED BLOWER

UNIT NUMBER DESCRIPTION

Digit #1, 2 - Unit Type [UT]

B2 - Power Vented Blower

Digit #3, 4, 5 - Capacity [CA]

100 - 100,000 BTU/HR
125 - 125,000 BTU/HR
150 - 150,000 BTU/HR
175 - 175,000 BTU/HR
200 - 200,000 BTU/HR
250 - 250,000 BTU/HR
300 - 300,000 BTU/HR
350 - 350,000 BTU/HR
400 - 400,000 BTU/HR

Digit #6 - Furnace Type [FT]

A - Right Side Access

Digit #7 - Heat Exchanger Construction Material [FM]

1 - Aluminized Steel
2 - 409 Stainless Steel
3 - 321 Stainless Steel

Digit #8 - Gas Type [GT]

N - Natural Gas
P - Propane Gas (LP)
K - Natural Gas w/100% Shutoff

Digit #9 - Ignition Control [IC]

2 - Spark Ignition

Digit #10 - Altitude [AL]

A - 0–1,999 ft.

J - 8,000–8,999 ft.

B - 2,000–2,999 ft.

K - 9,000–9,999 ft.

C - 3,000–3,999 ft.

L - 10,000–10,999 ft.

D - 4,000–4,999 ft.

M - 11,000–11,999 ft.

F - 5,000–5,999 ft.

N - Local Gas Supplier Derate

G - 6,000–6,999 ft. P

- Canadian High Altitude 2,000–4,500 ft.

H - 7,000–7,999 ft.

Digit #11 - Gas Control [GC]

A - Single Stage
B - Two Stage
H - Electronic Modulation w/Room Sensing
J - Electronic Modulation w/Duct Sensing
K - Electronic Modulation w/Duct Sensing & Room Override Stat
L - Electronic Modulation w/External 4-20 mA Input
N
- Electronic Modulation w/External 0-10 VDC Input

Digit #12 - Supply Voltage [SV]

1 - 115/1/60 5

- 230/3/60

2 - 208/1/60 6

- 460/3/60

3 - 230/1/60 7

- 575/3/60

4 - 208/3/60

Z - Special

Note: Supply Voltages [SV] 2-7 include fi eld mounted step down transformer.

Digit #13 - Motor Type [MT]

1 - Open Drip Proof
2 - Totally Enclosed
3 - Premium Effi ciency, Open Drip Proof
4 - Premium Effi ciency, Totally Enclosed

Digit #14 - Blower Motor Sizes [MS]*

A - 1/4 HP w/Contactor

M - 3/4 HP

B - 1/3 HP w/Contactor

N - 1 HP

C - 1/2 HP w/Contactor

P - 1/2 HP w/Magnetic Starter

D - 3/4 HP w/Contactor

R - 3/4 HP w/Magnetic Starter

F - 1 HP w/Contactor

S - 1 HP w/Magnetic Starter

G - 1-1/2 HP w/Contactor

T - 1-1/2 HP w/Magnetic Starter

H - 2 HP w/Contactor

U - 2 HP w/Magnetic Starter

J - 1/4 HP

W - 1/4 HP w/Magnetic Starter

K - 1/3 HP

Y - 1/3 HP w/Magnetic Starter

L - 1/2 HP
*Notes: 1. All 3-phase units [SV = 4, 5, 6, 7] include a contactor as standard.
2. All single phase units [SV = 1, 2, 3] include a contactor for units equipped with
1-1/2 HP. motor or higher [MS = G, H]
3. [MS] options J, K, L, M, N only available with single phase supply voltage [SV = 1, 2, 3].

Digit #15 - Accessories [AS]

FACTORY INSTALLED

A8 - Input Derate

S1 - 409 Stainless Steel Burners

S3 - 409 Stainless Steel Flue Collector

M8 - Discharge Duct Flange

P4 - Terminal Block Wiring
P6 - Summer/Winter Switch

† FIELD INSTALLED (AS-____ )

† Field Installed Accessories are not included in the Unit Number. All Field Installed
Accessories are entered as a separate line item using the catalog number which utilizes
“AS” as a prefi x. i.e: A7 becomes AS-A7.

A7 - Pressure Regulator 1/2-2 psi

H5 - Low Ambient Control

F1 - 1-Stage T675A Ductstat M2-1 - Vent Caps (4") (Unit Capacity 100-175)
F2 - 2-Stage T678A Ductstat

M2-2 - Vent Caps (5") (Unit Capacity 200-250)

M2-3 - Vent Caps (6") (Unit Capacity 300-400)

G1 - 1-Stage T87K Mercury Free Thermostat

M3-1 - Adaptors (5"- 4") (Unit Capacity 100-175)

w/Subase Kit

M7 - 2 to 4 Point Suspension Kit

G2 - 1-Stage T87K Mercury Free Thermostat
w/TG511A Guard Kit

P5 - 24V SPST Relay-Specify Purpose

G3 - 1-Stage T834N Mercury Free Thermostat
w/Fan Switch

Q1 - “Y” Splitter Nozzle

G5 - 2-Stage TH5220D Mercury Free

Q2 - 30 Degree Nozzle

Thermostat w/Subbase

Q3 - 60 Degree Nozzle

G6 - Locking Thermostat Cover

Q4 - 90 Degree Nozzle

G8 - 1-Stage T6169C Line Voltage Stat

Q5 - Poly Tube Adaptor (Unit Capacity 150-400)

w/Subbase

Q6 - Vertical Louvers

G9 - 1-Stage T822K Mercury Free

Thermostat



Digit

X X X X — 1 2 3 4 5 6 7 8 9 10

11

12

13

14

15 +

Item

Prefi

x

UT

CA FT

FM

GT

IC AL

GC

SV

MT

MS AS

(Internal use Only)