Vax15s used in an active system – Renkus-Heinz VAX15S User Manual

Page 21

Advertising
background image

NOTES:

1. The EQ settings shown are for a single array module and may need “fine tuning” in multi cabinet

arrays.

2. When the VAX101-15 is being used with a VAX15S subwoofer the VAX101-15 should be

delayed 2.7 ms.

Point Source Array Modules

Page 21

AMP GAIN

OUTPUT DELAY

POLARITY

CROSSOVER

CENTER FREQUENCY

40 Hz HP

80 Hz LP

TYPE

BUTTERWORTH BUTTERWORTH

SLOPE

24 dB/ Oct

18 dB/ Oct

NORMAL

0 dB

NONE

VAX15S USED IN AN ACTIVE SYSTEM

VA101-15-52 Series

VA101-15/6-52R: 60

o

H

VA101-15/9-52R: 90

o

H

VA101-15/12-52R: 120

o

H

VA101-15/69-52R: 60

o

to 90

o

H

(Transitional)

VA101-15/912-52R: 90

o

to 120

o

H

(Transitional)

VAX101-15 Series

VAX101-15/6: 60

o

H

VAX101-15/9: 90

o

H

VAX101-15/12: 120

o

H

VAX101-15/69: 60

o

to 90

o

Hl

(Transitional)

VAX101-15/912: 90

o

to 120

o

H

(Transitional)

Model Number & Horizontal Coverage Cross Reference

Advertising