- 17 -

Problem

Possible Cause

Possible Solution

9V DC battery clip not connected

Connect correctly

12-30V DC power source installation fault

Check installation

Master key switch not turned `ON'

Turn unit `ON' (vertical position)

Front cover fitted incorrectly

Check installation

Reversible mounting plate incorrectly installed

Check installation

Operating element depressed

Reset using reset key

Networked - The linked Alert Point is in `alarm'
condition

Reset the `networked' Alert Point

Tamper alarm activating

Check installation

Externally fitted detectors triggering Alert Point

Check linked units are not alarming

Networking DIL switch SW12 `ON' - but no
network required

DIL switch SW12 should be `OFF'

Connection lost between the `networked' Alert
Points

Check all wiring connections (including
COMMON)

5V6 zener diode not connected

Check detector terminals

Externally fitted detector connection broken

Check all wiring connections

9V DC battery output power insufficient

Low battery - change battery

DIL switch no. SW4 'ON' - the unit is expecting
external power, but not receiving any

Check ext power lead connections /
switch 'OFF' SW4 if no ext supply

Reset key not resetting Alert
Point when in `alarm' condition

Auto reset option turned `OFF'

DIL switch SW11 should be `ON'

No sound in `alarm' condition

Volume jumper connection loose or missing

Ensure the jumper connection is fitted
correctly

External sounder DIL switch SW6 turned `ON'

DIL switch SW6 should be `OFF'

External sounder connection fault

Check all wiring connections

External strobe/beacon DIL switch SW6 turned
`ON'

DIL switch SW6 should be `OFF'

External sounder connection fault

Check all wiring connections

No power

LED red & emitting a short beep
every 90 seconds

The Alert Point is constantly in
`alarm' condition

Tamper alarm sounding

External strobe / beacons not
flashing on activation

External sounders not alarming
on activation

LED red & emitting a short
double beep every 90 seconds

Troubleshooting

NEED TECHNICAL SUPPORT? FREEPHONE 0800 085 1678 (UK) TELEPHONE: +44 (0) 1527 520 999

General Maintenance:

9V DC batteries should be replaced every 15 months or sooner.
Cleaning should be carried out using only mild, diluted detergents: concentrated solutions and those
including (but not limited to) alkalis, strong acids, ethers, amines, aromatic hydrocarbons and
alcohols can cause considerable harm to this product.

E

x

te

rn

a

l

P

o

w

e

r

+

E

x

te

rn

a

l

P

o

w

e

r

-

N

e

tw

o

rk

I

N

N

e

tw

o

rk

C

OM

N

e

tw

o

rk

OU

T

R

e

lay

N

.O.

R

e

lay

C

OM

R

e

lay

N

.C

.

External Sounder +

External Sounder -
External Strobe/Beacon +

External Strobe/Beacon -

External Detector +
External Detector -

PCB Terminal Diagram

Terminal connections
External power terminals

12-30V DC

Relay terminals

Max 30V DC, 1A

External sounder terminals

All external sounders need to be hard wired using 2 core
cable and must have their own power supply.

External strobes / beacons terminals

All external strobes & beacons need to be hard wired
and must have their own power supply.

Detector terminals

All detectors need to be hard wired on a N.O. loop, have
their own power supply and an end of line 5V6 Zener
diode fitted (supplied with the unit).

Using the relay terminals, wire the positive loop connection into the N.O. terminal and the negative loop
connection into the COM terminal.

The unit will independently sound during `alarm condition’ as well as sending a trigger signal back the
alarm panel.

It is recommended that all external detector wiring does not exceed 50 metres.