Brocade FCX Series Hardware Installation Guide User Manual

Page 32

Advertising
background image

System status LEDs (Continued)

TABLE 12

LED

Condition

Status

Out-of-band ManagementLink or
Activity

On/Flashing Green The port has established a valid link at 10/100/1000

Mbps. Flashing indicates the port is transmitting and
receiving user packets.

Off

A link is not established with a remote port.

FIGURE 23 Power status LEDs

1.

Power status LEDs

Power status LEDs

TABLE 13

LED

Condition

Status

DC OK

Green

DC output ok

Red

DC output fail

AC OK

Green

AC input ok

Off

AC input fail

NOTE
Both "AC OK" and "DC OK" LEDs must be green for the device to function normally.

Switch status for two installed power supply units

TABLE 14

State

LED

PSU1 PSU2 Switch Status

Redundancy

Four Green PSU LEDs

AC OK Green Green Running

Yes

DC OK Green Green

Single Red ‘DC OK’ LED

AC OK Green Green Running

No

DC OK Green Red

Both ‘DC OK’ LEDs Red

AC OK Green Green Failure

No

Product Overview

30

Brocade FCX Series Hardware Installation Guide

53-1003077-01

Advertising