show mpls lsp_p2mp_xc

1

show mpls lsp_p2mp_xc

Displays hardware forwarding information

Syntax

show mpls lsp_p2mp_xc in_label

Parameters

in_label

Specifies the MPLS input label value.

Command

Modes

Privileged EXEC mode

Usage

Guidelines

The show mpls lsp_p2mp_xc command displays information about the forwarding information of
hardware that is allocated for the point-to-multipoint (P2MP) cross-connect.

Command

Output

The show mpls lsp_p2mp_xc command displays the following information:

Output field

Description

IN-LABEL

The incoming MPLS label value.

XC#

The XC index allocated for this instance.

FID

The FID resource allocated for a particular entry.

MVID

The MVID resource allocated for a particular entry.

IN-PORT

The port where the traffic arrives.

NUM_OUT_SEGS

The number of branches used by this instance.

BRANCH-ID

The branch ID used by this instance.

OUT-LABEL

The outbound MPLS label value.

OUT-PORT

The router port through which the device reaches the next hop for this
route path.

NH-ID

The next hop index used by this instance.

DIT

The downstream interface table (DIT) ID used by this branch.

TSI

The tunnel start interface (TSI) ID used by this branch.

Examples

The following example displays hardware forwarding statistics on a Brocade MLX Series device:

Brocade# show mpls lsp_p2mp_xc

P2MP XC TABLE:

TOTAL USED = 2

IN-LABEL XC# FID MVID IN-PORT NUM_OUT_SEGS

1159 0 0a00a 106 65535 1

1160 1 0a00b 107 65535 1

Brocade# show mpls lsp_p2mp_xc 1159

TOTAL OUT_SEGS under the given in_label = 1

BRANCH-ID OUT-LABEL OUT-PORT NH-ID

0 0 14 6

Event History -

Tue Aug 14 02:21:54 2012 P2MP BRANCH ADD

Tue Aug 14 02:21:54 2012 P2MP XC ADD