Power supply specifications (Continued)

TABLE 9

Specification

Value

System DC power consumption (excluding power supply and fan
FRUs)

Idle: 95 WMaximum: 116 W

Input system power (including power supply and fan FRUs)

Idle: 145 WMaximum: 173 W

Input voltage

85-264 VAC

Input line frequency

47-63 Hz

BTU rating

590 BTU/hr

Inrush current

Maximum of 60A for period of 10-150mS

Input line protection

Both AC lines are fused

Environmental requirements

The following table lists the acceptable environmental ranges for both operating and nonoperating (such
as during transportation or storage) conditions

Environmental requirements

TABLE 10

Condition

Acceptable during operation

Acceptable during non-operation

Ambient Temperature 0º to 40º C

32º to 104º F

-25º to 70º C

-13º to 158º F

Humidity

10% to 85% RH non-condensing, at 40º C (104º
F)

10% to 90% RH non-condensing, at 70º
C (158º F)

Altitude

0 to 3 km (9,842 feet) above sea level

0 to 12 km (39,370 feet) above sea level

Shock

20 G, 6 ms, half-sine wave

15 G, 12-18 ms, trapezoid

Vibration

0.5 G sine, 5-500 Hz

2.0 G sine, 5-500 Hz

Air flow

Maximum - 101.94 cmh (60 cfm)

Nominal - 74.76 cmh (44 cfm)

NA

Environmental requirements

Brocade 7800 Extension Switch Hardware Reference Manual

47

53-1001350-05

Advertising