Serial port specifications

The serial port is located on the port side of the Brocade 7800. The switch uses an RJ-45 connector for
the serial port. An RJ-45 to DB9 adaptor is also provided with the Brocade 7800.

NOTE
To protect the serial port from damage, keep the cover on the port when not in use.

The serial port can be used to connect to a workstation to configure the Brocade 7800 IP address
before connecting the switch to a fabric or IP network. The serial port’s parameters are fixed at 9600
baud, 8 data bits, and no parity, with flow control set to None.

Serial cable pinouts

TABLE 15

PIN

Signal

Description

1

Not supported

NA

2

Not supported

NA

3

UART1_TXD

Transmit data

4

GND

Logic ground

5

GND

Logic ground

6

UART1_RXD

Receive data

7

Not supported

NA

8

Not supported

NA

POST and boot specifications

The Brocade 7800 runs POST by default each time it is powered on; it typically requires from 1 to 3
minutes to boot and complete POST.

POST can be skipped after subsequent reboots by entering the fastBoot command. For more
information about this command, see the Fabric OS Command Reference.

POST

The success/fail results of the diagnostic tests that run during POST can be monitored through LED
activity, the error log, or a command line interface.

POST includes the following tasks:

1. Conduct preliminary POST diagnostics
2. Initialize the operating system