Post and boot specifications, Post, Boot – Brocade 6510 Hardware Reference Manual User Manual

Page 31: Interpreting post results, Post boot

Advertising
background image

POST and boot specifications

When the switch is turned on or rebooted, the switch performs POST. Total boot time with POST can be
several minutes. POST can be omitted after subsequent reboots by using the fastboot command or
entering the diagDisablePost command to persistently disable POST.

For more information about these commands, refer to the Fabric OS Command Reference.

POST

The success or failure results of the diagnostic tests that run during POST can be monitored through
LED activity, the error log, or the command line interface.

POST includes the following tasks:

1. Conducts preliminary POST diagnostics.
2. Initializes the operating system.
3. Initializes hardware.
4. Runs diagnostic tests on several functions, including circuitry, port functionality, memory, statistics

counters, and serialization.

Boot

In addition to POST, boot includes the following tasks after POST is complete:

1. Performs universal port configuration.
2. Initializes links.
3. Analyzes fabric. If any ports are connected to other switches, the switch participates in a fabric

configuration.

4. Obtains a domain ID and assigns port addresses.
5. Constructs unicast routing tables.
6. Enables normal port operation.

Interpreting POST results

POST is a system check that is performed each time the switch is powered on, rebooted, or reset.
During POST, the LEDs flash either amber or green. Any errors that occur during POST are listed in the
error log.

Complete the following steps to determine whether POST completed successfully and whether any
errors were detected.

1. Verify that the switch LEDs indicate that all components are healthy.

See

LED patterns

on page 29 for descriptions and interpretations of LED patterns. If one or more

LEDs do not display a healthy state, verify that the LEDs on the switch are not set to “beacon” by
entering the switchShow command to detect if beaconing is active.

2. Verify that the switch prompt displays on the terminal of a computer workstation connected to the

switch.

POST and boot specifications

Brocade 6510 Hardware Reference Manual

31

53-1002174-08

Advertising