Environmental requirements, General specifications, Environmental requirements general specifications – Brocade 6510 Hardware Reference Manual User Manual

Page 45

Advertising
background image

Environmental requirements

The following table lists the acceptable environmental ranges for both operating and nonoperating (such
as during transportation or storage) conditions.

Environmental requirements

TABLE 8

Condition

Acceptable during operation

Acceptable During Non-Operation

Ambient
Temperature

0º to 40º C (32º to 104º F)

-25º to 70º C (-13º to 158º F)

Humidity

10% to 85% RH non-condensing, at 40º C (104º F)

10% to 90% RH non-condensing, at
70º C (158º F)

Altitude

0 to 3 km (9,842 feet) above sea level

0 to 12 km (39,370 feet) above sea
level

Shock

20 G, 6 ms, half-sine wave

33 G, 11 ms, half-sine wave, 3/eg
Axis

Vibration

0.5 G sine, 0.4 gms random, 5-500 Hz

2.0 G sine, 1.1 gms random, 5-500
Hz

Air flow

Maximum - 71.36 cmh (42 cfm)

Nominal - 59.47 cmh (35 cfm)

NOTE: Airflow can be Forward or Reverse
depending on purchased option

NA

Heat dissipation

338 BTU/hr (32 port configuration)375 BTU/hr (48
port configuration)

NA

General specifications

The following table lists the general specifications for the Brocade 6510.

General specifications

TABLE 9

Specification

Description

Configurable port types

F_Port, E_Port, M_Port, EX_Port, and D_Port

System architecture

Nonblocking shared-memory switch

System processor

PowerPC 440EPx @ 667 MHz

ANSI Fibre Channel protocol

FC-PH ( Fibre Channel Physical and Signalling Interface standard)

Environmental requirements

Brocade 6510 Hardware Reference Manual

45

53-1002174-08

Advertising