Serial port specifications, Access gateway default port mapping – Brocade 6510 Hardware Reference Manual User Manual
Page 48
Serial port specifications
The serial port is located on the port side of the switch. The Brocade 6510 uses an RJ45 connector for
the serial port. An RJ45 to DB9 adaptor cable is also provided with the switch.
NOTE
To protect the serial port from damage, keep the cover on the port when not in use.
The serial port can be used to connect to a workstation to configure the switch IP address before
connecting the switch to a fabric or IP network. The serial port’s parameters are fixed at 9600 baud, 8
data bits, and no parity, with flow control set to None.
Serial cable pinouts
TABLE 12
PIN
Signal
Description
1
Not supported
NA
2
Not supported
NA
3
UART1_TXD
Transmit data
4
GND
Logic ground
5
GND
Logic ground
6
UART1_RXD
Receive data
7
Not supported
NA
8
Not supported
NA
Access Gateway default port mapping
The following table lists the port mappings of F_Ports to N_Ports.
Serial port specifications
48
Brocade 6510 Hardware Reference Manual
53-1002174-08