Environmental requirements

The following table lists the acceptable environmental ranges for both operating and nonoperating (such
as during transportation or storage) conditions.

Environmental requirements

TABLE 8

Condition

Acceptable during operation

Acceptable during nonoperation

Ambient Temperature 0º to 40ºC (32º to 104ºF)

-25º to 70ºC (-13º to 158ºF)

Humidity

10% to 85% RH non-condensing, at 40ºC (104ºF) 10% to 90% RH non-condensing, at

70ºC (158ºF)

Altitude

0 to 3 km (9,842 feet) above sea level

0 to 12 km (39,370 feet) above sea level

Shock

20 G, 6 ms, half-sine wave

33 G, 11 ms, half-sine wave, 3/eg Axis

Vibration

0.5 G sine, 0.4 gms random, 5-500 Hz

2.0 G sine, 1.1 gms random, 5-500 Hz

Airflow

Two power supply and fan units

• Maximum - 35.70 cmh (21 cfm)
• Nominal - 16.99 cmh (10 cfm)

One power supply and fan unit

• Maximum - not available
• Nominal - not available

NOTE: Airflow is port side exhaust.

N/A

Heat dissipation

338 BTU/hr (24 port configuration)

N/A

General specifications

The following table lists the general specifications for the Brocade 6505.

General specifications

TABLE 9

Specification

Description

Configurable port types

F_Port, E_Port, M_Port, EX_Port, D_Port

System architecture

Nonblocking shared-memory switch

System processor

PowerPC 440EPx @ 667 MHz

ANSI Fibre Channel protocol

FC-PH ( Fibre Channel Physical and Signalling Interface standard)