1 front panel keypad and annunciators – Rice Lake Condec UMC600 User Manual

Page 5

Advertising
background image

2

UMC600 Installation Manual

1.1

Front Panel Keypad and Annunciators

Figure 1-1 shows the UMC600 front panel. The UMC600 display consist of six seven-segment display digits.
Table 1-1 lists the front panel keys and their functions.

Figure 1-1. UMC600 Front Panel

1

6

2

7

3

8

4

9

5

0

CE

ENT

TARE

RECALL

NET

GROSS

TARE

lb/kg

CONV

PRINT

1 SET

POINT

2 SET

POINT

CAPACITY

5000 lb. X 0.5

ZERO

NET

GROSS

lb

kg

MOTION

ZERO

Low Battery Annunicator

Panel Key

Function

ZERO

Provides push-button auto zero (PAZ) over ±1.9% or 100% full scale capacity. Operates only in gross
weighing mode.

GROSS/NET

Switches the unit between gross and net weighing modes.

TARE

Provides push-button tare entry over 100% of scale capacity. Pressing TARE key switches to net mode
and enters tare.

PRINT

Provides a manual print function if unit is wired to serial printer or other data device. Also initiates truck
in/out weighing function if that feature is enabled. See Section 3.2 on page 20 for serial output
specifications.

lb/kg CONV

Switches the displayed weight unit between pounds and kilograms.

TARE RECALL

Press to recall tare value; LED annunciator lit when tare value is displayed. Also used as ID RECALL in

t

ruck weighing mode.

ON/OFF

Provides power to the indicator.

NOTE: On AC units, the ON/OFF switch is replaced by the blank key which becomes a start
key in setpoint batching modes.

SETPOINT 1 & 2

Push to enter or recall associated setpoint values.See Section 6.0 on page 49 for details.

0–9, CE, ENT

Numeric keyboard for entry of manual tare, setpoint values, and calibration data.

CE

(Clear Entry) and

ENT

(Enter) keys.

Table 1-1. Front Panel Key Functions