UTU-701 and ETU-751 List 1

Table 4

defines the system states indicated by the front panel LEDs. When power is applied to the unit, one of the

LEDs listed in

Table 4

will always be on.

Table 4.

Line and Desktop Unit Front Panel LED Indications

LED

Mode

Description

HDSL SYNC LED

Steady green

Slow blinking

Off

HDSL loop is ready to transmit and receive data across all spans.

HDSL loop acquisition is in progress for local span.

HDSL loop is not configured.

HDSL ALM LED

Steady red

Pulsing red

Off

Loss of sync word (LOSW); or the margin is below the set margin
alarm threshold; or Errored Seconds (ES) count is above
threshold on any span.

Pulses for every ES on any span.

Normal transmit or receive data is in progress.

I/F ALM LED

Steady red

Loss of Signal (LOS) alarm due to loss of G.703 signal or Loss of
Clock (LOC) alarm due t

o

loss of external clock (when using EXT

timing).

LPBK LEDs

(a)

LOC

REM

Steady yellow

Off

Local HDSL analog loopback is active.

Off

Off

No loopbacks are active.

Blinking yellow

Off

Local interface loopback is active.

Off

Steady yellow

Remote loopback is active.

Blinking yellow

Blinking yellow A loopback away from the local equipment is active.

(a)

The LOC and REM LPBK LEDs are read in unison.