5 meter calibration, 1 pre-calibration setup, 2 loup iii calibration procedure – Seed Hawk 30 SERIES 2015 User Manual

Page 52

Advertising
background image

SEED HAWK

®

2015 30 SERIES OPERATOR’S MANUAL – DOMESTIC 47

5.5.1 Pre-Calibration Setup

5.5 Meter Calibration

All meters must be individually calibrated. Calibrations must be done each time
a crop is changed. Calibration for the seed is done at the front hopper, on the
left side of the machine, and calibration for the fertilizer is done at the rear
hopper, on the right side of the machine. Measure and record the weight of the
empty calibration bag supplied.

1. Measure and record the weight of the empty calibration bag supplied.

Calibration Bag Weight: _________________

Once calibration bag is weighed, then attach the bag to the meter

5.5.2 Loup III Calibration Procedure

NOTE: It is important to cal-

ibrate as close to the actual

seeding rpm of the roller as

possible. Refer to Section 9.0

for the Seeding Table to get

an approximate roller rpm

for the specific roller and 

drill width.

1. Navigate the highlight bar to "Meter
Calibration" from the Menu Settings.

2. Highlight the desired meter to
calibrate.

Advertising