2015 30 SERIES OPERATOR’S MANUAL – DOMESTIC 49

5.5.3 Clear Field Acres

5.5.4 Rate Controller Meter Setup

This selection allows the operator to enter setup information for the meters.
The default screen is Meter 1. Other meters can be selected by pressing the
Soft Key for the desired meter.

1. Pulses per Rev: This is the num-
ber of pulses generated by the meter
sensor per 1 revolution of the meter
roller. This value is set by default but
can be manually entered. The default
value for a hydraulic drive system is
60.31 pulses per revolution.

2. Low Alarm Point: This is the minimum meter rpm speed the meter can
turn before the “low meter rpm” or “meter stopped” alarms will display. The
default value is 0.5 rpm.

3. Weight/Rev: This value is determined by the Meter calibration procedure or
it can be manually entered.

1. Move monitor to Aircart and
power up
2. Select Meter Calibration
3. Select desired meter to calibrate

4. Prime roller
5. Calibrate Meter
6. Enter weight of product

Loup III Quick Start Calibration

Choosing this item allows the user to clear the accumulated field acres. 

NOTE: If total acres cannot

be cleared from the settings

menu, contact your Seed

Hawk dealer for information

on clearing the register.

NOTE: Once verified the 

field acres cannot be re-

stored.

1. Using the Selector Knob, high-
light "Clear Field Acres."

2. A dialog box will appear verifying
your selection. Verify by pressing the
Selector Knob or the Enter Key.