Spectra Precision ProFlex 800 Web Server User Manual

Page 33

Advertising
background image

29

• Unless already done, please follow all the steps described

in section General Parameters on page 16 before
proceeding with the steps below.

• Still on the

Rover Setup page, in the Serial Port x pane

corresponding to the port you want the receiver to use (A,
B or F), set the following parameters:

Connection: Choose the name of the corrections
receiver device connected to the port. As a general
rule, choose “None/Cable” for any external corrections
receiver connected to that port. But if the device used
is a license-free radio, type ARF7474B EU or
ARF7474A NA, choose specifically this type of radio.

– Port settings (

Baud Rate, Mode, RTS/CTS): Set the serial

port to match the external device connected to it.
Setting these fields will update the corresponding
fields on the

Serial Ports sub-menu page

• At the bottom of the page, in the

Differential Port pane,

select the

Automatic option to let the receiver detect the

incoming differential stream automatically.

NOTE:

Automatic is the recommended choice for the

Differential Port setting because in this case, you don’t
need to define the ports receiving the two possible
differential streams.

• Click on the

Configure button to let the Web Server load all

your new parameters to the receiver.

• If the external radio used is a standalone, non-identified

radio receiver, skip this step. But if an ARF7474x license-
free radio is used, click on the

Connections> Radio

submenu and from the

Type field located in the External

Radio pane, select the type of license free radio used.
Then click on the

Configure button.

• If port A is used for the connection to the external radio,

you just have now to define the output messages (see
Defining Output Messages on page 30). But if port B or F
is used, there is an additional step needed (see below)
before you define the output messages.

• If port B or F is used for the connection to the external

radio, click on the

Connections> Serial Ports submenu,

enable the

Power ON option for serial ports B & F (bottom

of the page) and click on the

Configure button. You can

switch to the output message definition.