Ntrip server via ethernet, Internet – Spectra Precision ProFlex 800 Web Server User Manual
Page 52
48
NTRIP caster (the server) to which it is supposed to deliver
its corrections.
Enable
Connect Now to allow the receiver to establish the
connection right after you have clicked on
Configure.
• In the
Message field, select the type of differential data the
base will deliver (ATOM, RTCM, CMR, CMR+ or DBEN).
Following your selection, through a click on the “I”
symbol, you will see the detail of the selected data on the
right of this field, as defined in
Data Output > Differential
Messages.
• Click on the
Configure button to let the Web Server load all
your new parameters to the receiver. You have now
reached the end of the configuration phase.
NTRIP Server Via
Ethernet
CAREFUL: In the RTCM sense, an “NTRIP server” is a source
of corrections feeding an NTRIP caster (see RTCM paper
200-2004/SC104-ST). But from the point of view of the
network terminology, an “NTRIP server” is a client, not a
server.
As explained earlier (see How to Start on page 34), in that
configuration you can define one or two NTRIP servers
sending their data streams either to an external NTRIP caster
(see first figure below) or to the embedded NTRIP caster (see
second figure below). All combinations are possible. Choose
the ones that meet your requirements.
ProFlex 800
RTK Corrections
Ethernet
Users
IP address
or server name
Internet
(Client)
NTRIP Caster
One or Two
NTRIP Servers
ProFlex 800
Ethernet
Users
(NTRIP clients)
External
NTRIP servers
Internet
Embedded
NTRIP Caster
One or Two
NTRIP Servers