By default the

Caster Hostname or IP Address field shows the

local IP address of the receiver (the one that can be read
on the receiver display screen).

If the Ethernet port is set to work in DHCP and you have
declared a hostname on the DynDNS site, then the field
should be updated to hold that hostname.

If on the contrary, the public IP address to communicate
with the receiver is a static address, then it should be
known to the station administrator and entered in that
field.

By default the

Caster Port Number field reads “2101”. This

value should not normally be changed.

• Define a password that NTRIP servers will have to provide

for being authorized to connect to the NTRIP caster as
correction data providers. Enter this password in the
Caster Password field. The password can be displayed in
plain by clicking on the

Show Characters button.

• Use the

Maximum Simultaneous Connections per User field to

increase the number of connections a user can make at a
time (default: 1). The upper limit is 100.

• Use the

Caster Information area to enter informative data

about the NTRIP caster. The whole set of information
entered in this area will be made available to NTRIP caster
users through the so-called NTRIP Source Table.

• Click on the

Configure button to load all the NTRIP caster

settings to the receiver.

• Click on

Embedded NTRIP Caster > Mount Points. Use this tab

to define all the mount points the NTRIP caster will have
to manage. Behind each mount point is a base station
installed at a given location and generating a given data
format.

While most of the data presented to define a mount point
are mostly informative (identifier, data format,
approximate location of the base, country, fee indicator),
the

Name field on the contrary is the key parameter

through which the NTRIP caster will organize the
connections between NTRIP servers and NTRIP clients
(users). So each mount point name should be chosen to
depict as accurately as possible the source of corrections
available through the mount point. Making all those
names as short as possible is also recommended for the
convenience of NTRIP clients.

For example, the mount point corresponding to a base
station installed near the town of Balville and generating