6. Move the instrument for the next level turn and then start a new shooting

sequence.

If the foresight point is a turning point, tap

Turn to Turning Point again. If the

foresight point is a point of interest (i.e. a benchmark), tap

Turn to

Benchmark. In both cases, proceed as explained above.
Again, Survey Pro will provide results at the end of the second level turn
that you will need to accept by tapping

Store Observation. Additionally for a

benchmark, you will need to enter a name and description for that point.
This may be an existing point in the job (select it from the list or the map),
in which case Survey Pro will prompt you to update its elevation, or a new
point, in which case Survey Pro will create this point with just its elevation.
Tap

to continue.

7. For the last level turn, tap

Turn to Benchmark when you are ready for the

shooting sequence. Proceed in the same way as for any benchmark.

The difference is when you name the point once the observation is
accepted, you will have to select the closing CBM from the list of existing
points. In our example, this point is also the opening CBM, a point named
“CBM”. Survey Pro will then alert you that this point cannot be modified
but will give you the option to close the level loop (see screen example).

8. Tap

Close Loop on Existing Point. Survey Pro will then provide a report on the

level loop you are about to close.

9. Tap

Close Level Loop. A message informs you that the loop has been closed

successfully.

10.Tap

OK. Survey Pro goes back to the loop summary screen from which you

will notice that no more action can be taken for the loop.

11.Tap

to return to the home screen.