The general operations are as below:

▲▼◄►

(Mouse: Left click)

Press these buttons to select the items.

Numeric

Press these buttons to select the alarm input.

COPY

(

)

Press this button to copy the settings of the focus alarm input to all the following
alarm inputs. (EX. focus alarm input is 1, its settings will be copied to those of
alarm inputs 2-4.)

ESC

(Mouse: Right Click)

Press this button to escape from this screen, and return to Setup Menu display. If
the Save dialog is shown, press

ENTER

to exit and save,

ESC

(Mouse: Right

Click)

to exit without saving.


Following is a brief description for each item and its specific operations:

Normal State – press

+/-

buttons to select N/A, Close or Open. Please check

the signal type, normally close or normally open, connected to the alarm input
terminal on the rear panel of the system. If there’s no signal connected, please
select N/A – Not Available, and the following items will not be settable. The
default setting is Open.

Title – The title (Max. 8 characters) of this alarm input. Please follow the Text
Input method described in

Section 4.1

to modify this item.

Focus Camera – the camera corresponding to this alarm input.

Duration – response duration to define at most how long (in seconds) the Alarm
Out relay and the Buzzer will keep being triggered after this alarm input is
triggered. However, the Alarm Out relay and the Buzzer will be reset
immediately once this alarm input returns to normal. Press

+/-

buttons to adjust

the value (3 seconds - 60 minutes, discrete, ‘-‘ for ‘Forever’).

Goto Preset – to define the preset position to go to for the Focus Camera if this
alarm input is triggered and the Focus Camera is a PTZ camera. For more
details about preset locations, please refer to

Chapter 7 PTZ Control

.

Pre-record – to define how long before this alarm input is triggered the Focus
Camera shall be intensively recorded at Pre-record IPS. Press

+/-

buttons to

adjust the value (0-10 seconds, discrete). Please note that the actual pre-record
time may be shorter than the value set if the total size of the pre-record pictures
exceeds the pre-record buffer size of the system.