HT instruments PQA824 User Manual

Page 59

Advertising
background image

PQA400 - PQA823 - PQA824

EN - 58

Press SAVE or ENTER keys (or the smart icon

) to save each selection and confirm by

“Ok” . The main screen of Fig. 89 is shown by meter at the end of the operation.
Press ESC key (or the smart icon ) to quit without saving and go back to previous
screens.

5.4.10. Unbalance

The selection of this option include on selected parameters list for recording the value of
NEG% and ZERO% s which are index of unbalance of input voltage signal respective to
negative tern and zero term (see § 10.5). “Unbalance” is not shown for single phase
systems.

5.4.11. Spike (only PQA824)

This option permits to set the control parameters relative to recording of voltage fast
transients (spike) events (see § 10.6) with 5

s resolution which is completely independent

from periodic analysis (regulated by integration period). The below screen is shown by
meter:

12/09/2006 – 16:55:10

RECORDING SETTINGS

+

Harmonics

Voltage Anom.: 230V 6%-10%
Inrush current: 30A 1s fix

Flicker

Unbalance

Spike: 150V

100/251 Parameters – Autonomy: 21d 0h

CLP/EXP

PREDEF.

SEL

MODIFY

Fig. 110: Spike setting screen


Press F4 key (alternatively touch MODIFY at display) for setting the parameter for
detection and recording of voltage spikes. In particular is possible to set:

The value of voltage threshold to detection and recording the voltage spike event from

meter. This value s selectable from 100V and 5000V value.

12/09/2006 – 16:55:10

RECORDING SETTINGS

+

Harmonics

Voltage Anom.: 230V 6%-10%
Inrush current: 30A 1s fix

Flicker

Unbalance

Spike: 150V

Spike:

150

MOD(+)

MOD(-)

Fig. 111: Spike screen - setting control parameter


1. Move the cursor using arrows keys on field relative to “Spike” , marked it with blue

background.

Advertising
This manual is related to the following products: