INOR PROFIPAQ-L User Manual

Page 7

Advertising
background image

7

2.3 Short form Data (complete data in chapter Specifications)

Power supply

9 – 32 VDC

Isolation

Input/Output

1500

VAC

Output

ProfIbus

PA

Profile v. 3.0 Class A&B

Operating temperature ProfIPAQ-H/-HX

-40 - +85 °C / -40 - +185 °F

ProfIPAQ-L

-20 - +70 °C / -4 - +158 °F

2.3.1 Ex Data (also see certificate and control drawings)

ProfIPAQ-H / -H/D

ProfIPAQ-HX / -HX/D

ATEX Approval

Gas

II 3G Ex nL IIC T4-T6

II 1G Ex ia IIC T4-T6

Dust

II 3GD Ex nL T 100°C

II 1G/2D Ex ia IIC T 100°C


ProfIPAQ-H/ -H/D is intended to be connected to a standard power supply (Class 2) with

maximum supply voltage to the transmitter of 30 VDC or a FNICO power supply / Segment

coupler, mounted outside the hazardous area. The data for the transmitter is:
Bus-port (connector 6 and 7)

Sensor port (1- 5)

Comm.port

Ui = Vmax :

30 VDC

Uo = Voc : 3,3 VDC

Ui = Vmax : 8,0 VDC

Ii = Imax :

no limit

Io = Isc : 0,4 mA

Ii = Imax : 450 mA

Pi = Pmax :

no limit

Po = Pt : 6,5 mW

Pi = Pmax : 0,8 W

Ci :

1 nF

Co = Ca : 500 µF

Ci :

10 nF

Li :

10 µH

Lo = La : 375 mH

Li :

1 µH


For the ambient temperature:

T6:

-40°C < Ta < +60°C / -40°F < Ta < +140°F

T5:

-40°C < Ta < +75°C / -40°F < Ta < +167°F

T4:

-40°C < Ta < +85°C / -40°F < Ta < +185°F

Dust:

-30°C < Ta < +80°C / -22°F < Ta < +176°F

ProfIPAQ-HX / -HX/D is intended to be connected to a certified intrinsic safe power

supply / Segment coupler with FISCO data, mounted outside the hazardous area. The data
for the transmitter is:

Bus-port (connector 6 and 7)

Sensor port (1- 5)

Comm.port

Ui = Vmax :

17,5 VDC

Uo = Voc : 17,5 VDC Ui = Vmax : 8,0 VDC

Ii = Imax :

380 mA

Io = Isc : 56 mA

Ii = Imax : 450 mA

Pi = Pmax :

5,32 W

Po = Pt : 244 mW

Pi = Pmax : 0,8 W

Ci :

1 nF

Co = Ca : 166 nF

Ci :

10 nF

Li :

10 µH

Lo = La : 6 mH

Li :

1 µH

For the ambient temperature:

T6:

-40°C < Ta < +45°C / -40°F < Ta < +113°F

T5:

-40°C < Ta < +60°C / -40°F < Ta < +140°F

T4:

-40°C < Ta < +85°C / -40°F < Ta < +185°F

Dust:

-30°C < Ta < +80°C / -22°F < Ta < +176°F

Advertising