Table 1-2. bop general specifications, Bop general specifications -2 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.4.08 to 4.11 User Manual

Page 22

Advertising
background image

1-2

BOP HIPWR 070212

TABLE 1-2. BOP GENERAL SPECIFICATIONS

SPECIFICATION

RATING/DESCRIPTION

CONDITION

INPUT CHARACTERISTICS

a-c voltage

nominal

230 Va-c

Single phase, or between two phases of a 3-
phase system

range

176 - 264 Va-c

Frequency

nominal

50/60 Hz

range

47 - 63 Hz

Current

176 Va-c

9.5A (7.5A)*

maximum

264 Va-c

6.4A (4.4A)*

maximum

Power factor

Source

0.99 minimum

nominal output power

Sink

0.97 minimum

Efficiency

65% (56%)*

minimum when sourcing

Switching frequency

70 KHz ±5% (50KHz ±5%)*

Active PFC Input for both Source and Recu-
peration (Sink)

EMC Compliance

EN61326-1 (1997)

Class A equipment

EMC immunity to:

ESD

EN61000-4-2

Electrostatic discharge

Radiated RF

EN61000-4-3

EFT

EN61000-4-4

Electrical fast transient/burst

Surges

EN61000-4-5

Conducted RF

EN61000-4-6

EMC emissions

Conducted

EN61000-3-2

harmonics

EN61000-3-3

fluctuation & flicker

Conducted

EN55011/CISPR11

0.15 to 30 MHz

Radiated

EN55011/CISPR11

30 to 1000 MHz

Leakage current

3.5 mA

230V a-c, 47-63 Hz

Insulation coordination

Input

Installation Category II

For TN or TT power system

Overvoltage Category II

Output

Installation Category II

Maximum 300V common mode voltage
between output terminals and chassis ground.

Overvoltage Category II

Pollution degree

2

OUTPUT CHARACTERISTICS **

Type of stabilizer

Voltage-current, 4-quadrant

Switch mode

Switching frequency

100KHz ±5%

Output Stage

Source adjustment
range

voltage

-100% to +100% of rating

0 to 50 deg C

current

-100% to +100% of rating

Sink adjustment range

voltage

-100% to +100% of rating

0 to 50°C, recuperated energy is sent
back into line for general reuse

current

-100% to +100% of rating

*

BOP 6-125MG and BOP 10-75MG only.

** Output characteristics are for a single standalone unit. Output characteristics of identical multiple unit parallel/series configurations

are described in the Technical Manual associated with the applicable Cable Kit (see Table 1-5).

Advertising