Table 2-13. slave status message definitions, 10 power on default screen for master unit -23, 13 slave status message definitions -23 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.4.08 to 4.11 User Manual

Page 61: 13 f, Re 2-10)

Advertising
background image

BOP HIPWR 070212

2-23

1. Adjust the limits to reflect the increased power capacity of the multiple unit combination as

follows:

a. From the main screen, press

%

to enter the General Setup Menu.

b. From the General Setup menu, Highlight Max/Min Settings and press

!

. Press

@

to

restore defaults. Verify that the Max/Min settings reflect the multiple unit combination. For

example, for a parallel combination the values for +Current Max, –Current Min and ±Cur-

rent Protect Max/Min now reflect the total current of the parallel combination. Voltage val-

ues and limits reflect a series combination. For 2 X 2 and 3 X 2 combinations both current

and voltage are affected. NOTE: If desired, these limits may be lowered as described for a

standalone unit (see PAR. 3.3.4).

c. Press

$

to save the settings upon power-up, then

%

to exit the General Setup menu and

return to the power-up screen

FIGURE 2-10. POWER ON DEFAULT SCREEN FOR MASTER UNIT

TABLE 2-13. SLAVE STATUS MESSAGE DEFINITIONS

Slave Status Message

Displayed on Master Power Up Screen

(see Figure 2-9)

MEANING

Ready

Unit is ready for operation.

STANDBY

If unit’s FAULT indicator is off, hardware error has NOT been detected,
output is ready to be turned on

No Answer

Unit is not responding to polls via BITBUS.

Faulted

Unit’s FAULT indicator is on to indicate a hardware error has been
detected.

Not Used

Unit is not part of parallel configuration

Unknown

Waiting for interface communication

Mode Error

Slave does not match voltage/current or parallel/series configuration
expected by master.

VOLTAGE

SOURCE