3-24

BOP-1K-GL 022814

3.5.7.3

WAVEFORM SPECIFICATIONS

Refer to Table 1-2 for specifications applicable to waveforms created using LIST commands.

FIGURE 3-7. SAMPLE WAVEFORM

3.5.7.4

EXECUTING A WAVEFORM

These segments are programmed using the LIST:CURR:APPLy (PAR. B.57) or
LIST:VOLT:APPLy (PAR. B.79) commands. The details of the waveform segments are defined
in Table 3-6. Once the waveform segments are added to the list, the list is executed by sending
either CURR:MODE LIST (PAR. B.27) or VOLT:MODE LIST (PAR. B.94).

TABLE 3-5. SQUARE WAVEFORM FREQUENCY VS. POINTS

Frequency

(See Note)

Total Points

Frequency

(See Note)

Total Points

From

To

From

To

0.02Hz

1.8Hz

3840

43.51Hz

58.0Hz

120

1.81Hz

2.7Hz

2880

58.01Hz

72.5Hz

90

2.71Hz

4.0Hz

1920

72.51Hz

87.0Hz

72

4.01

5.4Hz

1280

87.01Hz

108.7Hz

60

5.41

7.2Hz

960

108.71Hz

145.0Hz

48

7.21Hz

10.8Hz

720

145.2.9Hz

174.0Hz

36

10.81

16.3Hz

480

174.1Hz

217.5Hz

30

16.31Hz

21.7Hz

320

217.6Hz

261.0Hz

24

21.71Hz

27.1Hz

240

261.1Hz

435.0Hz

20

27.11Hz

32.6Hz

192

435Hz

652.5Hz

12

55.5Hz

66.5Hz

160

653

1000

10

NOTE: Time interval per point is inversely proportion to frequency variation within the range.