75

Record reading main screen

Item Item

Description

1A & 1B

(A) Current output 1/ level in mA/mm; (B) Current output 2/ interface level in mA/mm

2A & 2B

Tank diagram showing current position of (A) level and (B) interface.

3

Dead zone limit

4A, B & C (A) Distance/ level of top product in mm, (B) Interface distance/ interface level of

bottom product 2 in mm, (C) Ullage volume/ volume in liters* (*configurable display).

5

Date of time slice

6

Time of time slice

7

F6: Trend function – shows level and interface over time recorded

8

F1: Help – on-line help function

9

F7 : Signal – shows return signal received by gauge at a given time and date

10

F2 : Configuration – access to user menu. The settings here are read-only. This list will
also show modifications to the gauge settings over the time measurement data is
recorded

11

F8 : Markers – Error indicators activated at a given time and date

12

F3 : Exit Record Reading window

13

F9 : Colors – change screen component colours as shown in Section 9.4.7

14

F10 : Screen copy – function for saving bitmaps of the current screen.

15

AltF1: Oscilloscope – to display signal amplitude/return signal time at a given day and
time.

16

+: playback functions

Advertising