INDEX

INSTRUMENT PANEL FEATURES

INSTRUMENT PANEL FEATURES

2

FUNCTIONS MENU

3

GETTING STARTED

4

Initial Set-up

4

AUTOTUNE

4

Tune or tune at setpoint program

5

PROPORTIONAL CYCLE-TIME

5

Cycle-time recommendations

5

SECOND AND THIRD SETPOINTS (SP2 and SP3)

5

Error messages

6

LINEAR INPUT

6

Set-up procedure

6

FUNCTION LIST

7

Level 1

7

Level 2

7

Level 3

8

Output Options Table

8

Re-transmission

8

Level 4

9

Level A

10

PROGRAMMER

11

Function overview

11

Getting started (Programmer)

12

Program run mode

12

Display functions

12

Example program

13

Function map

14

Function list

16

Memory allocation table

17

Memory full indicator

17

Programming example

18

Program edit example

18

MECHANICAL INSTALLATION

19

DIN panel cut-out

19

Mounting

19

Cleaning

19

ELECTRICAL INSTALLATION

19

Typical application

20

Input options (diagrams)

21

Output options (diagrams)

21

INPUT SENSOR SELECTION

22

Temperature sensors

22

Linear input

22

SPECIFICATION

22

SAFETY AND WARRANTY

23

2

Right Red LED:
Program Holdback
indicator

Orange Display:
Setpoint value or
program selection

Green LED:
Setpoint 1 output indicator

Upper Red LED:
Setpoint 2 output
indicator

Lower Red LED:
Setpoint 3 output
indicator

Green Display:
Process variable or
Function/Option

ADJUSTMENTS

To enter or exit program mode: Press

▲ ▼ together for 3 seconds

To scroll through functions: Press

▲ or ▼

To change levels or options: Press

✱ ▲ together or ✱ ▼ together

To view setpoint units:

Press ✱

To increase setpoint:

Press ✱ ▲ together

To decrease setpoint:

Press ✱ ▼ together

To reset latched alarm or tune fail:

Press ▲ ▼ together briefly

To run or Hold a program:

Press ✱ ▼ together for 3 seconds

Notes:

If in difficulty by becoming “lost” in program mode, press ▲ and ▼ together for 3
seconds to return to display mode, check the INSTRUMENT ADJUSTMENTS above and
try again.

When in program mode, after 60 seconds of key inactivity the display will revert to
either

inPt : nonE

or, if the initial configuration has been completed, the measured

value. Any settings already completed will be retained. During Program Configuration it
is recommended that this feature is inhibited. Select

ProG StAY

in Level 4.

This page can be photocopied and
used as a visual aid and bookmark when
working in other parts of the manual.

!