Console functions, Masters – Audient ASP4816 - Compact Analogue Recording Console User Manual

Page 30

Advertising
background image

Page -30-

© Audient Ltd

Console functions.

COMPRESSOR

A compressor can be switched into

the main stereo signal path when

required. Note that it is located af-

ter the mix insert point but before

the main fader.

The compressor characteristics are

optimised for use in mix processing

while many of the parameters remain

under the control of the engineer.

Threshold, Gain Make Up, Attack,

Release and Ratio are all adjustable

while the entire processor can be

switched out of circuit when not

required.

A bargraph meter indicates the

amount of compression applied to

the signal. When compression is

taking place this should show some

very healthy activity. Please do not

try to over compress the mix output

as the results will sound terrible.

Always use your ears to check the

effect that you are trying for!

A good use of the compressor may

be to limit peak signals by setting a

highish threshold with a high ratio.

Thus when the threshold is reached

the signal is barely allowed to

increase beyond it.

1 A 12 segment bargraph

METER indicating the

amount of gain reduction

taking place.

2 THRESHOLD control for

determining the level where

compression starts. Threshold

can be set between -20dBu

and +20dBu.

3 ATTACK controls the speed

with which the compressor

reacts. Attack is adjustable in

6 steps from 0.1 to 30ms.

4 RATIO determines the amount

of compression used once the

signal is above the threshold

level. For example a ratio of

2:1 means that the output will

rise 1dB for every 2dB rise in

input level.

Ratios of 4:1 and 10:1 are also

available.

5 MAKEUP is a gain control.

When a signal is compressed

the level is reduced. A gain

make up stage restores the

peak level although of course

the dynamic range of the

signal has now been reduced.

40dB of gain is available.

6 RELEASE controls the speed

at which the compressor

allows the gain to return to

normal when the signal drops

below the threshold level.

Release is available from

0.1s to 2.4s in 5 steps with an

additional AUTO setting.

7 The IN switch puts the

compressor into circuit.

MASTERS

Advertising