IR Programming Buttons

Reading

Button Label

Displays For

Description

Endpoint Technology

Encoder Type

Quick Read

All

All

Initiates an RF Quick Read for the selected endpoint

High Power

CE

All

Forces a brief high powered signal from the endpoint to a

gateway receiver

Program/

Force Read

All

All

Toggles, based on the encoder type For ORION water endpoints

with an RTR, Program is used to set the endpoint odometer value

following a tamper repair With an ADE or HR-E LCD encoder or with

an E-Series meter, Force Read is used to view the real-time encoder

odometer value

Read Endpoint

All

All

Initiates IR communication between the software and the endpoint

Radio Status

Button Label

Displays For

Description

Endpoint Technology

Encoder Type

Start

All

All

Starts endpoint radio "On-Mobile Mode" is shown in the

Radio Status field

Stop

All

All

Stops endpoint radio "Stopped" is shown in the Radio Status field

A stopped endpoint must be reprogrammed to begin transmitting

again With an ORION Migratable or Fixed Network endpoint, the

endpoint historical interval data (profile data) is cleared when the

endpoint is restarted

Pause

All

All

Pauses endpoint transmission temporarily until a unit of water or gas

is registered "Paused" is shown in the Radio Status field

Meter Information

Button Label

Displays For

Description

Endpoint Technology

Encoder Type

Change

ME, SE

HRE, ENC,

RTR, Gas

For water meters, used to change the meter size, type and/or units of

measure For gas meters, used to change the drive circle (units, dials

and resolution), pressure and direction

CE

Gas

GPS Location (ORION ME and SE only)

Button Label

Displays For

Description

Endpoint Technology

Encoder Type

Set GPS

Location

ME, SE

All

Brings up a window in which you can enter the latitude and longitude

for the endpoint

Flow Rate Study (ORION ME and SE only)

Button Label

Displays For

Description

Endpoint Technology

Encoder Type

Start

ME, SE

All

Used to start the flow rate study

Get

ME, SE

All

Used to get the results of the flow rate study

Save

ME, SE

All

Used to save the flow rate study results Displays where the file

is saved

IR PROGRAMMING