Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 39

Advertising
background image

Result: Profile data for the endpoint is extracted. The screen fills as shown below when the data has been retrieved.

Figure 50: IR profile extraction complete

IR Profile Extraction Details

Oldest Reading

The date and time of the oldest reading in the data extracted

Newest Reading

The date and time of the newest reading in the data extracted

Interval

The reading interval at which the endpoint is set: 60 Minutes or 15 Minutes

Quantity

The number of interval reads retrieved

Status Indicators

Potential exception issues such as a tamper or no usage If no exceptions are noted, none of

the boxes are checked

6 Use the buttons to Save Data or Clear Data You can also select Change Interval to change the time between

historical interval meter readings

Save Data

Select to save the profile data A window displays with a message that confirms the save and

the location of the file as shown in Figure 51 Click OK to close the window

Figure 51: Save file confirmation

Change Interval Select to change the interval (60 minutes or 15 minutes) for meter readings Changing the

interval clears any stored interval data A window opens, asking you to confirm the change

Clear Data

Select to clear all historical interval profile data from the endpoint A window opens, asking you

to confirm the change

7 The IR Profile Extraction is complete To access profile data for another endpoint, repeat steps 2…6

PROFILE EXTRACTION

Page 39

April 2014

ORION® Endpoint Utility

Advertising
This manual is related to the following products: