Follow this procedure for programming an RTR endpoint to the odometer setting

1 On the IR

programming screen,

double-click in the

Current Reading field

to select the current

read value

Figure 22: Current Reading field

2 Using the keyboard,

enter the RTR

odometer value

in the Current

Reading field

Result: The field

background is

highlighted to indicate

an unprogrammed

value has been entered.

Figure 23: Current Reading field highlighted

3 Align the optical head

of the IR cable with

the endpoint IR LED

port and click the

Program button

Hold the optical head

of the IR cable steady

The endpoint is

programmed when

the background in the

Current Reading

field clears

Figure 24: Current Reading field programmed

OTEE:

N

The Status Indicators are also updated to show Index Changed and Endpoint Programmed

Programming Water Meter Type, Size and Units of Measure (RTR, ADE)

To program the water meter type and size for an RTR or ADE, follow these steps

OTEE:

N

The water meter type, size and units of measure for endpoints connected to an HRE or ELCD encoder type are

obtained from the encoder and are not programmable

1 Align the optical head of the

IR cable with the endpoint

IR LED port

2 Click Read Endpoint

if a reading is not

already registered

3 Click the Change button

in the Meter Information

section of the screen
Result: The Change Meter

Information window opens.

Figure 25: Change button

4 Scroll through the list

and click to select the

appropriate Meter Size And

Type and Unit Of Measure

5 Align the optical head of the

IR cable with the endpoint

and click Program
Result: The new Meter

Information is displayed on

the IR Programming screen as

shown. The Status Indicators

are also updated to show

Endpoint Programmed

Figure 26: Meter Size, Type, Unit of Measure

Figure 27: Meter Type, Size, Unit of Measure programmed

OTEE:

N

For gas meters, see

"Programming Gas Endpoints" on page 27