Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 25

Advertising
background image

Programming Water Meter Type, Size and Units of Measure (RTR, ADE)

To program the water meter type and size for an RTR or ADE, follow these steps

OTEE:

N

The water meter type, size and units of measure for endpoints connected to an HRE or ELCD encoder type are

obtained from the encoder and are not programmable

1 Align the optical head of the

IR cable with the endpoint

IR LED port

2 Click Read Endpoint

if a reading is not

already registered

3 Click the Change button

in the Meter Information

section of the screen
Result: The Change Meter

Information window opens.

Figure 25: Change button

4 Scroll through the list

and click to select the

appropriate Meter Size And

Type and Unit Of Measure

5 Align the optical head of the

IR cable with the endpoint

and click Program
Result: The new Meter

Information is displayed on

the IR Programming screen as

shown. The Status Indicators

are also updated to show

Endpoint Programmed

Figure 26: Meter Size, Type, Unit of Measure

Figure 27: Meter Type, Size, Unit of Measure programmed

OTEE:

N

For gas meters, see

"Programming Gas Endpoints" on page 27