PROCEDURES FOR MOUNTING THE ORION REMOTE ENDPOINT

The ORION remote endpoint can be installed in any indoor or outdoor, non-submersible location

Placement

For maximum efficiency the ORION remote endpoint should be placed between 36 and 72 inches off of the ground

Orientation

The ORION remote endpoint should be mounted in a vertical orientation with the open portion of the housing at the bottom

Location

The ORION remote endpoint can be placed near a meter or volume corrector It can be mounted on a pipe using the supplied

stainless clamp or to a flat surface using screws The pipe can be either horizontal or vertical

36" - 72"

Endpoint Mounted
to a Horizontal Pipe

Open Portion
of Housing

Open Portion
of Housing

Endpoint Mounted
to a Vertical Pipe

ORION® Gas Endpoints, Remote Endpoint for Gas Meters and Volume Correctors with Pulsed Outputs