Gas rt connections, Gas rt connections 19 – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 19

Advertising
background image

CONNECT THE ORION REMOTE ENDPOINT TO A TWO-CONDUCTOR

CABLE FROM A METER OUTPUT

If connecting a endpoint to a pair of wires, determine the proper length of wire needed from the ORION remote

endpoint and from the pulser

1 Trim about 3/4 inch of the outer sheath from both ORION wires This exposes the two individual wires in each

NOTE:

N

Do not remove the insulation from these wires

2 Insert the two ORION remote endpoint positive (+) polarity wires into a gel cap Make sure the two wires are inserted

fully and seated in the gel cap

A three-wire gel cap should be used with the negative (-) polarity wire of the meter output going to the black and green wires

of the ORION unit

GAS RT CONNECTIONS

NOTE:

N

For detailed instructions, see the Model GAS RT Installation Data sheet

If a Badger Meter gas RT (Recordall® endpoint) is used as the source of the signal, the wires are spliced into the gas RT
The gas RT is installed on the index cover face

Gel-caps are provided for splicing ORION remote endpoint cables to gas RT cables

Gas RT

Gas RT Cover

Gas RT Attached to
the Index Cover Face

Two-Wire Gel
Cap for gas RT
Red Wire and
ORION Remote
Endpoint Red
Wire

Three-Wire Gel
Cap for gas
RT Black Wire,
ORION Remote
Endpoint
Black Wire and
ORION Remote
Endpoint Green
Wire

Installation Manual

Page 19

July 2013

Advertising
This manual is related to the following products: