Milestone Basis+ 6.5 User Manual

Page 125

Advertising
background image

Milestone XProtect Basis+ 6.5; Administrator’s Manual

www.milestonesys.com Page

125

Logging

LogCheck_20070615.log. The log check file is by default placed in the folder containing the
XProtect Basis+ software, typically C:\Program Files\Milestone\MilestoneSurveillance\.

Any inconsistencies will be reported in the form of error messages written in the log check file. The
following table lists possible error messages (other, non-error, messages may also appear in the

log check file):

Error Message

Description

”Log integrity information was not

found. Log integrity can’t be

guaranteed.”

The log file could not be checked for integrity.

”Log information does not match

integrity information. Log integrity

can’t be guaranteed.”

The log file exists, but does not contain the

expected information. Thus, log integrity cannot

be guaranteed.

”[Log file name] not found.”

The log file was not present.

”[Log file name] is empty.”

The log file was present, but empty.

”Last line changed/removed in [log
file name].”

The last line of the log file did not match validation
criteria.

”Encrypted data missing in [log file
name] near line [#].”

The encrypted part of the log line in question was
not present.

”Inconsistency found in [log file
name] near line [#].”

The log line does not match the encrypted part.

”Inconsistency found in [log file

name] at beginning of log file.”

The log file header is not correct. This situation is

most likely to occur if a user has attempted to

delete the beginning of a log file.

Advertising