Milestone Basis+ 6.5 User Manual

Page 96

Advertising
background image

Milestone XProtect Basis+ 6.5; Administrator’s Manual

case simply select Output 1.

Keep output for: Specify the amount of time for which the output should be active

when triggered, in either 1/10 seconds or seconds.


Note: Some devices are only able to apply outputs for a relatively short time, for

example max. five seconds. Refer to the documentation for the device in question

for exact information.

External output name: Specify a name for the output. The name will appear on

the list with which users will be able to manually trigger the output. Note that

output names must not contain the following characters: < > & ‘ " \ / : * ? | [ ]

In the example to the right, we have specified that a

siren connected on a camera’s Output 1 port should

sound for five seconds when triggered:

Tip: You are able to test the output by clicking the

Test Output button.


When ready, click OK. This will return you to the I/O

Setup window (see page 74).

4. In the I/O Setup window, your newly defined output is now listed (you may have to click

the expand icon in front of the name of the camera or other device to see the listing):

Click OK to close the I/O setup window and return to the Administrator window (see page

26).

5. In the Administrator window (see page 26), first select the camera for which the output

should be available, then click the Settings... button.

This will open the Camera Settings for [Device Name] [Camera Name] window (see page

39).

6. In the Camera Settings for [Device Name] [Camera Name] window, click the Outputs...

button:

www.milestonesys.com

Page 96

Input, Events & Output

Advertising