Table 3: Filter Flow Rates @ 20 gpm/ft

2

(13.58 lps/m

2

)

Filter Model

SMF2- FG

Forward Flow

GPM / LPS

Minimum

Backwash Flow

GPM / LPS

Maximum

Backwash

Flow

GPM / LPS

20

43 / 2.7

32 / 2

43 / 2.7

24

63 / 3.97

47 / 3

63 / 3.97

30

98 / 6.2

74 / 4.7

98 / 6.2

36

141 / 8.89

106 / 6.7

141 / 8.89

42

192 / 12.11

144 / 9

192 / 12.11

48

241 / 15.2

180 / 11.4

241 / 15.2

Table 4: Electrical Requirements - Single Phase

PUMP

HP / KW

Voltage 1

φ

60HZ / 50HZ

Full Load Current (Amps)

0.5 / 0.38

110, 208, 220

9.8, 5.0, 4.9

1 / 0.75

110, 208, 220

16, 8.8, 8

1 / 0.75

110, 208, 220

16, 8.8, 8

2 / 1.5

110, 208, 220

24, 13.2, 12

Advertising