SMF2-FG Series Media Filter

Operating & Maintenance Manual

PEP Filters

• 322 Rolling Hill Road • Mooresville, NC 28117 • 800-243-4583 •

www.pepfilters.com

704-662-3133 (Outside USA) Page 4 of 16 Fax 704-662-3155

rev. 01/02

stress on piping.
Check with local, county, or other government authorities to ensure compliance with

applicable government industry requirement codes.
NOTE: The filter vessel drain plug is located on the tank bottom for 20”, 24” and 30” units,

and on the side near the tank bottom for 36”, 42” and 48” units.

ACTUATOR REQUIREMENTS
PEP SMF-FG filters utilize electric actuators to control the valve action between the filtration

and backwash modes. The electric actuator is designed for 110 VAC control.

LOADING THE FILTER MEDIA
The special spherical silica sand media used in all PEP Industrial Water Filters is designed

to remove over 95% (by volume/weight) of all suspended solids. The media will ship to

the jobsite in 0.5 ft

3

(14,160 cu. cm.) drums @ 50 lb./drum or in 1 ft

3

(28,320 cu. cm.)

bags @ 100 lbs./bag for easy handling during the media loading process.
1. NEVER LOAD MEDIA INTO A DRY FILTER TANK, fill tank one-third to one half full with

water before loading. Always check filter internals before loading media. This procedure is

the same for Unigran 55 and 85. Refer to Table 6 for appropriate media quantities for a

specific filter size.

WIRING
PEP Industrial Water Filters supplied with a pump and automatic backwash controls are

provided with the following as standard: UL Type 4X control cabinet containing an on/off

disconnect switch, motor overload protection, transformer to provide 110v control voltage,

backwash timer, 24 hour time clock, pressure differential switch to initiate backwash, valve

actuator to reposition valves for backwash, and push button for manual backwash

initiation. Units are provided with the customer requested voltage/phase (460 volt, three

phase standard). Check the current draw upon initial start-up and make sure that it is

equal to or less than the prescribed value shown in Table 4.
Units supplied with city or other source backwash are provided with a magnetic motor

starter. Units supplied as manual are provided with no motor control of any kind.


THE FOLLOWING RECOMMENDATIONS CONFORM TO THE 1993 NATIONAL ELECTRIC