CODE. CHECK WITH LOCAL, COUNTY, OR OTHER GOVERNMENT AUTHORITIES FOR

PRESCRIBED REQUIREMENTS.
NOTE: CHECK FILTER PUMP NAMEPLATE FOR HORSEPOWER AND AMP DRAW

Single Phase Manual Units
1. Install a separate power supply line with circuit breaker protection between the closest

branch distribution panel and the pump motor. The full load current for standard models is

listed in Table 4.
2. Install an externally operated switch with fuse protection and door interlock in plain

sight of the filter and not more than 50 feet (15m) away. The thermal overload protection,

if required, must be sized for full load amp draw listed on the pump motor name plate.
Three Phase Manual Units
1. Install a separate power supply line with circuit breaker protection between the closest

branch distribution panel and the pump motor. The full load current for standard models is

listed in Table 5.
2. Install a service disconnect switch in plain sight of the filter and not more than

50ft/15m away.
3. Install an externally operated manual or magnetic starter with thermal overload and

fuse protection. If the unit is to be controlled remotely with a time clock, switch, or other

device, a magnetic starter must be used. The thermal overload protection, if required,

must be sized for the full load amp draw listed on the pump motor nameplate.
Single and Three Phase Automatic Units
1. Install a separate power supply line with circuit breaker protection between the closest

branch distribution panel and the control box. The full load current for standard single and

three phase units is listed in Tables 4 & 5. The control box contents are pre-wired and

include a service disconnect switch, thermal overload, a transformer to convert the power

supply to single phase 110v for controls. Wire the power supply lines to the disconnect

switch. ALL INCOMING POWER SUPPLY LINES MUST CONNECT TO DOOR INTERLOCK

DISCONNECT.

24 HOUR/7-DAY TIME CLOCK
The 24-hour time clock (standard, unless equipped with a PLC) is used to initiate the 2

minute backwash timer relay at any specified time in the day. The 24 hour backwash clock