SMF2-FG Series Media Filter

Operating & Maintenance Manual

PEP Filters

• 322 Rolling Hill Road • Mooresville, NC 28117 • 800-243-4583 •

www.pepfilters.com

704-662-3133 (Outside USA) Page 15 of 16 Fax 704-662-3155

rev. 01/02

Table 5a. Electrical Requirements / Three Phase (60 Hz)

PUMP Motor

HP / KW

Voltage 3

φ

60 HZ

Full Load Current (Amps)

1 / 0.75

208, 230, 460, 575

4, 3.6, 1.8, 1.4

2 / 1.5

208, 230, 460, 575

7.5, 6.8, 3.4, 2.7

3 / 2.24

208, 230, 460, 575

10.6, 9.6, 4.8, 3.9

5 / 3.73

208, 230, 460, 575

16.7, 15.2, 7.6, 6.1

Table 5b: Electrical Requirements / Three Phase (50Hz)

HP / KW

Voltage 3

φ

50 HZ

Full Load Current (Amps)

1 / 0.75

380, 415

1.7, 1.6

2 / 1.5

380, 415

3.4, 3.1

3 / 2.2

380, 415

5.2, 4.7

Table 6. Media Quantities: SMF-FG

Model

SMF2-FG

Unigran 55 & 85

(50 lb. pails)

Unigran 475 – (for under-drain

support, 50 lb. bags)

20 4

-0-

24 5

-0-

30 8

-0-

36 10

9

42 15

12

48 22

19

Advertising