Ps0, ps1, and ps2 – period select, Ratio, Odir – oscillator direction – PNI ASIC User Manual

Page 12: Mot – magnetic oscillator test, Aso & asi – axis select, Function, 2 mhz scaling, X axis, Y axis, Z axis

Advertising
background image

PNI ASIC 

Host Processor Interface 

PS0, PS1, and PS2 – Period Select


Selects the division ratio applied to the L/R oscillator output to set the period being measured

.

Table 11: Period Select

PS2

PS1

PS0

Ratio

0

0

0

/32

0

0

1

/64

0

1

0

/128

0

1

1

/256

1

0

0

/512

1

0

1

/1024

1

1

0

/2048

1

1

1

/4096


ODIR – Oscillator Direction

Determines the magnetic oscillator direction if MOT is set to 1. It has no effect on direction when the MOT
bit is set to zero. This is used for debug purposes only, and will not be set in normal operation.


MOT – Magnetic Oscillator Test

When set, causes the magnetic oscillator selected by AS0 and AS1, in the directions selected by ODIR to
run continuously until PNI ASIC is reset.


ASO & ASI – Axis Select

Determines which axis is being measured.

NOTE

When 2 MHz scaling is selected, the magnetic sensor oscillator does not run. Instead, the internal
2 MHz oscillator is turned on. The 2 MHz clock cycles are counted until a command byte is sent
disabling the scaling function. A RESET stops the 2 MHz oscillator and clears all bits.

Table 12: ASO and ASI Axis Select

Function

AS1

AS0

2 MHz scaling

0

0

X axis

0

1

Y axis

1

0

Z axis

1

1

PNI Corporation  133 Aviation Blvd., Suite 101, Santa Rosa, CA  95403‐1084  USA;, Fax: (707) 566‐2261 
For the most current specifications, please visit our website at: 

www.pnicorp.com

  

 

‐ 12 ‐ 