Parameter voltage and current levels, Vila, Iilb – PNI ASIC User Manual

Page 3: Iola, Electrical specifications

Advertising
background image

PNI ASIC 

Specifications 

Electrical Specifications


Parameter voltage and current levels

Testing for the currents listed in

Table 4

assume a static test setup with measurements performed while

static data is applied to the device. Test type parameters apply as listed in the

Table 8: Pin Definitions

Table 4: Inputs

Test Type

Vil

a

Vih

a

Iil

b

Iih

b

AIB (analog input)

0.2 Vdd

2.0 Vdd

0.0 to -1.0 µA

0.0 to 1.0 µA

IBA (CMOS)

0.25 Vdd

0.8 Vdd

0.0 to -1.0 µA

0.0 to 1.0 µA

IBT (CMOS, SC
Hsy = 1.0)

c

0.2 Vdd

0.8 Vdd

0.0 to -1.0 µA

0.0 to 1.0 µA

a.

CMOS values are V

IN

x V

DD

.

b.

Iil and Iih are tested at V

DD

= 3.6 V. Not tested at less than room temperature.

c.

SC = Schmitt

Table 5: Outputs

Test Type

Vol Voh Iol

a

Ioh

a

OB 1

b

<0.4 V

>2.4 V

1.0 mA minimum

-1.0 mA minimum

OB 2

b

<0.4 V

>2.4 V

1.0 mA minimum

-1.0 mA minimum

OB 3

c

0.267 V

1.936 V

10 mA minimum

10 mA minimum

a. Polarity on currents indicate direction of current ( + ) for sinking ( - ) for sourcing.

b. V

DD

= 4.5 to 5.0 V

c.

V

DD

= 2.2 V

Table 6: I/O Pins

Test
Type

Vil

a

Vih

a

Vol

b

Voh

b

Iol

b

Ioh

b

Ioz

c

Ioz

c

IO1A
CMOS

<.30 V

>.70V

<0.40 V

4.1 V

-0.64 mA

-0.15 mA

39µA
minimum

217 µA
maximum

a. CMOS values are V

IN

x V

DD

.

b. Tested at V

DD

= 4.8 V

c.

Tested with V

DD

= 5.2 V. Leakage on I/O pins is typically checked for ± 2 µA with the ouput device turned off and no

PU or PD.

PNI Corporation  133 Aviation Blvd., Suite 101, Santa Rosa, CA  95403‐1084  USA;, Fax: (707) 566‐2261 
For the most current specifications, please visit our website at: 

www.pnicorp.com

  

 

‐ 3 ‐ 

Advertising