Connections, Installation – ProMariner Combi Inverter Charger User Manual

Page 14

Advertising
background image

I n s t a l l a t i o n G u i d e l i n e s

24

23

Connections

I n s t a l l a t i o n G u i d e l i n e s

Installation

AC IN

Marking

Description

Color

L

Line or Hot

Black

L2

Line 2 or Hot on 220 VAC applications only

Red

N

Neutral

White

G

AC Ground

Green or Green
w/ Yellow Stripe

AC OUT

Marking

Description

Color

L

Line or Hot. (Black). To 110 VAC powered

Black

appliances (main panelboard or split bus
or L1 loads on 220 VAC)

L2

Line 2 or Hot on 220 VAC applications only (Red).

Red

To 110 VAC powered appliances (main panelboard
or split bus or L2 loads on 220 VAC)

N

Neutral (White)

NOTE: This Neutral shall not be

White

connected to the ground other than at the designated
power source (e.g. TruePower Combi, Shore/station
power, generator) The internal transfer switch in this
unit maintains isolation until connected. Ensure that
existing transfer strategies do the same.

G

AC Ground

Green or Green
w/ Yellow Stripe

DC IN/OUT

Marking

Description

Color

+

Battery Positive = Positive Battery charge lead

Red

as well as power feeder for invert mode

-

Battery Negative = Negative Battery charge lead

Black or Yellow

as well as negative return for invert mode.

Earth

Safety Ground connected to the boats

Green or Green

DC grounding bus. This conductor is essential to

w/ Yellow Stripe

shock and fire prevention and carries current
as a result of a fault. AC Ground

! DO NOT OPERATE THIS UNIT WITHOUT THE EARTH CONNECTION ATTACHED.

The earth conductor is permitted to be 1 size smaller than the DC Positive (+) conductor
(Example: DC += 2 AWG, Earth = 4 AWG)

DC POWER SUPPLY

ProMariner Minimum Recommended Battery or Battery Bank is 200 Ahr.

Series vs. Parallel - 2 types of battery connections exist; either installation can be used
with the TruePower Combi.

Series - Batteries connected in order to boost voltage while maintaining amp-hour ratings.

Parallel - Batteries connected in order to boost amp hours while maintaining voltage.

The two scenarios are easily illustrated:

INSTALLATION MATERIALS – CABELING

1) DC Cables - The DC portion of the TruePower Combi requires a large amount
of amperage in Inverter Mode. Cable size and length is of extreme importance

and should be well thought out and planned per this manual before
beginning installation. Items to consider are as follows:

a. Cable Size - Size is based on amperage draw of the unit compared
to the maximum amperage a cable can carry based on ABYC E-11.
ProMariner recommends NO MORE THAN a 10% drop in voltage from
source (battery) to the TruePower Unit or a cable run longer than 5 feet.

The following table outlines the cable size based on unit size.

Recommended Cable Sizes
(Based on UL 1426 105

° C Jacket Temperature Rating)

Series Batteries (12V)

for a 24V Bank

(Increases System Voltage)

Parallel Batteries (12V)

for a 12V Bank

(Increases the Amp/Hr Capacity)

12V Battery

12V Battery

12V Battery

12V Battery

Advertising