Appendix 1 Load Calculations

Appendix 1 Load Calculations

LEG A

LEG B

Total Amperes
Exhaust and supply fans
Air conditioners*,**
Electric, gas or oil heaters*
25% of largest motor in above items
Sub-total

LEG A

LEG B

Disposal -10%
Water Heater - 100%
Wall Mounted Ovens – 75%
Cooking Units - 75%
Refrigerator -100%
Freezer – 100%
Ice Maker - 50%
Dishwasher - 25%
Washing Machine – 25%
Dryer - 25%
Trash Compactor – 10%
Air Compressor - 10%
Battery Chargers – 100%
Vacuum System - 10%
Other Fixed Appliances
Sub-Total
**Adjusted Sub-Total

NOTE: **If four or more appliances are installed on a leg, adjust the sub-total
of that leg by multiplying by 60% diversity factor.

NOTES:
* Omit smaller of these two, except include any motor common to both functions
** If system consists of three or more independent units adjust the total by multiplying

by the 75% diversity factor

11.8.2.2.1

Add nameplate amperes at indicated use factor percentage for fixed loads:

11.8.2.2.1

Determine Total Loads

LEG A

LEG B

Lighting, receptacles, and small appliances
(from E-11.8.2.2.1.1, E-11.8.2.2.1.2)
Motors and heater loads (from E-11.8.2.2.3)
Fixed appliances (from E-11.8.2.2.4)
Free standing range (See NOTE 1)
Calculated total amperes (load)

NOTES:
1. Add amperes for free standing range as distinguished from separate oven and cooking
units. Derive by dividing watts from Table III by the supply voltage, e.g., 120 volts or 240 volts.
2. If the total for Legs A and B are unequal, use the larger value to determine
the total power required

NAMEPLATE RATING

USE

(WATTS)

(WATTS)

10,000 or less

80% of rating

10,001 – 12,500

8,000

12,501 – 13,500

8,400

13,501 – 14,500

8,800

14,501 – 15,500

9,200

15,501 – 16,500

9,600

16,501 – 17,500

10,000