Menu structure for batch blenders – Sterlco SGBD Series Batch Gravimetric Blenders User Manual

Page 40

Advertising
background image

BLN1-600

Chapter 3: Installation

40 of 110

Menu Structure for Batch Blenders

Recipe Page—Start

Ø

Change Recipe Values by
touching the number you
wish to change

Ø

Touch “Accept New Recipe”
button after you’ve made the
desired changes

Ø

Touch “Undo” button to
cancel a recipe change
before accepting it

Ø Start or stop the blender by

touching the “Push to Start or
Stop” button

Ø Access “Recipe Book ” Page
Ø Access “Clean Out” Page
Ø Access “Inventory” Page”
Ø Access “Setup” Page

“Recipe Book” Page
Save the running recipe to the
book.
• Delete a stored recipe
• Load a stored recipe
• Erase all stored recipes
• Modify the product ID for a

stored recipe

• Return to the Recipe Page

“Clean Out” Page
• Empty the blender hoppers
• Manually operate mixer,

weigh hopper dump gate,,
and slide gate below mixer

• View/test all inputs/outputs

on the blender

• Return to Recipe Page

“Inventory” Page
• View/print accumulated

inventories

• View batch time
• View maximum capacity
• View average process rate
• Return to Recipe Page

“Setup” Page
• Touch the “ACS” icon and

enter in user password

Recipe Format

Percentage, Parts, or
EZ mode

Metering order

Batch size

Inventory shutdown

“Batch ready” mode

“Auto start” mode

Weigh every batch
options

Change recipe
without stopping

Report Setup
• Blender number
• “Auto print” option
• “Auto clear” option
• “Auto interval” option
• Auto start time

Calibration
• Scale Calibration
• Direct Scale Readout
• Feeder Calibration

Mixer & Dump Setup
• Mixing time
• Remix time
• Dump time
• Dump delay
• Dump cycles
• Mixer dump time
• Time/continuous mixing

option

Panel View “Config”
• View software version
• Access Panel View “Config”

setup to modify printer/time
settings and to load new

software

User Password
• Change default user password

Units
• Blender data units (lbs/kg)
• Target v. actual data units

(lbs/kg)

Alarm Log
• View, print, or clear alarm log

Alarm Setup

“Stop/Continue” when
out of material

“Alarm/No Alarm” when
out of material

“Alarm Silence” delay

Accept recipe alarm
enable/disable

Missing ingredient

Network Setup

IP Address

Subnet Mask

Send Config to ENI
Module

Enable Ethernet
Configurator

Modbus Plus Disabled

User Interface Lock
• Lock the user interface to

prevent others from making
changes or viewing the blender

Advertising