Sterlco SGBD Series Batch Gravimetric Blenders User Manual

Page 43

Advertising
background image

BLN1-600

Chapter 3: Installation

43 of 110

6. Subtract the values recorded in step 4 from step 5. This is the measured weight. If

the measured weight is within a 0.003 pounds of the weight stamped on the
calibration weight, then you are within spec. If not, follow the steps above to
calibrate the blender. (If your blender is frequently out of calibration, verify the
operator is being cautious removing the weigh hopper during clean out.)

7. Press “Done” until you have reached the Recipe screen.

8. ***Anything in the Diagnostics Menu that is not covered here is in the Detailed

Controller Setup Section***

Feeder Calibration (AF & RAM Components)

Feeder calibration should be done on all Auger components prior to start-up. This allows the
blender to configure the parameters which will best suit the auger size and gearbox ratio of
the feeder. To perform a feeder calibration, the operator must enter the “Feeder
Calibration”
screen (see menu structure), select a feeder number, then touch “Press Here.”
The feeder calibration will start automatically and will notify the operator when complete. If
the operator so desires, they can repeat the process by entering in a new feeder number and
touching the “Press Here” button.

If the blender does not see enough weight gain during the calibration process or if the weigh
hopper reaches maximum weight, then an error is given and the calibration is a failure.
Another useful feature on the “Feeder Calibration” screen is the ability to manually enter in
the “weight per second” values. This increases the blender learning process and the values
can be recorded for future blending.

Alarm Setup

This screen allows the operator to configure the alarm settings for each individual feeder. It
can configure whether a feeder will retry during the metering of a batch, and enable or disable
the “Out of Material” alarm for any feeder. If the alarm flag is set to “Stop”, the blender will
not continue. It stops on that component continuing to try and meter. The optional low level
proximity switches have their own separate alarm. The alarm will sound, but does not stop
the blender. To configure each hopper do the following:

1. Enter the Setup Menu.

2. Once in the Setup menu, press “Alarm Setup.” This will take you to the “Alarm

Flags & Feeder Setup” screen.

Figure 30: Display Alarm Flags & Feeder Setup Screen


3. Select a feeder (1-6) by touching the “Select Feeder” box.

4. The current settings for the hopper that you have chosen will now be shown on the

screen.

Enable or Disable
Retries

Enable or Disable
Alarms

Go back to Setup
Directory

Change the Alarm
Silence Delay

Select a Feeder to
Configure

Advertising