Chapter 7: Appendix

98 of 110

Network Setup

This screen allows the blender to be configured for use with the Ethernet Option. The
blender will automatically configure the Ethernet module’s IP Address and Subnet Mask if
the configurator is enabled. Whenever you modify the IP Address or subnet, you either need
to reboot the PLC or touch “Send Ethernet Config to Module.”

Figure 77: Typical Ethernet Setup Screen

Alarm Setup

This screen allows the user to configure the feeder type for each feeder; configure whether a
feeder will retry during the metering of a batch, and enable or disable the “Out of Material”
alarm for any feeder. If a hopper is set to “No Retry” then the blender will continue to meter
the rest of the batch even if this hopper runs out of material. No “Out of Material” alarm will
be given regardless of how the alarm is configured unless the user has purchased and wired in
the low level proximity switches in each hopper. To configure each hopper, perform the
following steps:

1. Select a feeder by touching the “Select Feeder” box.

2. The current settings for that hopper will be shown.

3. Make the necessary adjustments and select a new feeder to configure if desired.

4. Hit “Done” to exit.

Figure 78: Typical Alarm Flags & Feeder Setup Screen

Go back to

Setup

Directory

Enable or

Disable the

Ethernet Module

Configurator

Enable or Disable

Alarms

Go back to Setup

Directory

Change Blender’s

IP Address and

Subnet Mask

Select a Feeder to
Configure

Enable or Disable

Retries

Change the Alarm
Silence Delay